Geotechnical borehole logging is the systematic recording of soil, rock, groundwater, drilling conditions and test results encountered during a subsurface investigation. A borehole log ties observations to measured depths so that geologists and geotechnical engineers can build a defensible ground model for foundations, excavations, slopes, roads, tunnels and groundwater works.
A professional log is more than a list of soil names. It documents how each conclusion was reached, which intervals were actually sampled, where material was lost, and how reliable the observations are. This guide covers field logging, soil and rock descriptions, core recovery, RQD, groundwater records, sample coding, a worked borehole example and quality-control checks.
What Is a Geotechnical Borehole Log?
A geotechnical borehole log is the depth-based record of an investigation hole. It normally combines factual observations made by the logger and driller with results of sampling or in-situ testing. The final report may also show interpreted geological contacts, but it must distinguish observations from interpretation. A log of one point does not establish the continuity of layers between boreholes.
Borehole logging serves three related purposes: documenting the materials actually encountered, preserving the provenance of samples and measurements, and providing an auditable starting point for engineering design. The exact format varies by site, contractual specification and jurisdiction; national practice and the chosen logging standard should be stated.

Field Logging and Final Borehole Logs
A field log is completed during drilling, sampling and coring. It contains first-hand details such as drill-run intervals, changing penetration rates, sample depths, drilling fluid losses and initial groundwater observations. A final log is a checked presentation that incorporates laboratory identifications, corrected test values, surveyed elevations or revised interpretations where justified.
Corrections should be traceable. For example, a soil described in the field as ‘brown silty sand’ may later be assigned a formal classification after grading and plasticity tests. The original description should remain recoverable, rather than being silently overwritten. Downhole geophysical logs are different measurements and are described separately below.
Before Drilling: Required Borehole Information
The header of a log identifies where, when, how and why the hole was drilled. Without these details, even excellent core descriptions may be difficult to use alongside nearby boreholes or design drawings.
| Field | What to record |
|---|---|
| Borehole identification | Unique hole ID, project, site and exploration objective |
| Position and datum | Surveyed coordinates, coordinate reference system, ground-level elevation and vertical datum |
| Drilling operation | Dates, contractor, drilling rig, logger, drilling method and hole diameter |
| Intervals and equipment | Casing depths, core-barrel or sampler type, drilling fluid, tool changes and hole inclination |
| Measurements | Depth convention, sampled intervals, test method, units and instrument calibrations where applicable |
| Water and completion | Water strikes, time of observations, measured levels, installations, backfill and final hole depth |
All depths should use one clearly stated reference point, normally measured downward from ground level or a documented casing reference. If a wellhead or casing is higher than the ground surface, show the offset. Where a log displays elevations rather than depths, elevations require a surveyed ground-level datum.
Step-by-Step Borehole Logging Procedure
- Confirm the location and setup. Match the hole ID, coordinates, planned depth and sampling schedule to the investigation plan. Record the drilling method, safety arrangements and any changes to equipment.
- Log continuously as the borehole advances. Document cuttings, soil samples, rock core, drilling response, visible contacts and changes in material. Do not invent an exact lithological boundary where no reliable sample was recovered.
- Identify and label every sample. Record unique sample number, top and bottom depth, sample type, recovery and intended laboratory tests. Maintain sample custody and protect moisture-sensitive specimens.
- Describe the material systematically. For soils, record constituent fractions, grading, colour and condition. For rock, record lithology, weathering, strength estimates and discontinuities, using a consistent standard.
- Integrate measurements with depth. Enter in-situ test results at their test intervals; document equipment or procedure deviations rather than presenting results as directly comparable.
- Review the log before leaving the site. Check depths, contacts, missing intervals, water observations, photographs, core boxes and the driller’s record. Reconcile inconsistencies while the evidence is still available.
Field records should be legible and sufficiently detailed to support a later independent review. A high-quality photograph is helpful, but it does not replace a depth-referenced description or a reliable sample label.
How to Describe Soil Samples
Field soil identification is primarily visual and manual; laboratory testing may then support formal classification. ISO 14688-1 addresses identification and description, while ISO 14688-2 addresses classification principles. Applicable national rules and project specifications should be followed.
Useful characteristics include principal soil fraction, secondary constituents, particle sizes, angularity, grading, colour, plasticity, consistency or relative density, visible structure, organic material, carbonate reactions and moisture condition. Descriptions should avoid unsupported precision: hand tests do not yield a laboratory plasticity index, and an SPT N-value is not itself a field description of soil texture.
| Observation | Example field description | Important distinction |
|---|---|---|
| Grain-size composition | Brown fine- to medium-grained SAND, slightly silty | Confirm percentages and grading by laboratory tests when needed |
| Fine-grained material | Grey CLAY, firm, high-plasticity appearance | Plasticity class needs appropriate laboratory assessment |
| Gravel | Sandy GRAVEL with subrounded clasts | State clast size and grading, not just a broad name |
| Structure | Thin silt laminae, fissured clay or root traces | May reveal depositional or post-depositional features |
| Moisture/condition | Moist, wet or visibly saturated | A wet recovered sample alone does not locate the water table |

When comparing nearby boreholes, the logger should look for evidence of fill, organic soil, reworked deposits, thin weak layers and abrupt grading changes. Such features can have greater engineering significance than the average properties of a thick unit.
How to Describe Rock Core
Rock-core logging addresses both intact rock material and the rock mass. ISO 14689:2017 provides an international basis for rock identification, description and classification, but engineering projects should also follow the applicable contract, geological context and national adoption.
Record rock type, mineralogy where observable, grain size, colour, weathering or alteration, visible fabric, bedding or foliation, veins, strength indications and any soluble or weak components. Separately document joints, fractures, faults and other discontinuities: their spacing, persistence where determinable, roughness, aperture, infilling, weathering and measured orientation when defensible from an oriented core.

A core run can cross more than one lithological unit. Depths assigned to each material and discontinuity should be recorded within the run, not inferred solely from the total box length. Natural broken surfaces may indicate joints, while freshly broken surfaces created by drilling or handling should not automatically be logged as pre-existing geological fractures.
Core Recovery and Rock Quality Designation (RQD)
Total core recovery (TCR) expresses the total length of recovered core divided by the drilled run length. Rock Quality Designation (RQD) is the summed length of sound core pieces at least 10 cm long, expressed as a percentage of the core run length, with drilling-induced breaks interpreted appropriately. It is a descriptive index, not a direct measurement of rock mass strength.
For a hypothetical one-metre run, assume the recovered pieces are 18, 7, 22, 14, 4, 13, 9 and 7 cm long. Their total recovered length is 94 cm. Only the 18, 22, 14 and 13 cm sound pieces meet the 10 cm RQD threshold in this simplified example.
| Quantity | Calculation | Result |
|---|---|---|
| Total core recovery | 94 cm ÷ 100 cm × 100 | 94% |
| RQD | (18 + 22 + 14 + 13) cm ÷ 100 cm × 100 | 67% |
| Unrecovered interval | 100 cm − 94 cm | 6 cm |

The calculation changes if pieces separated by obvious mechanical handling breaks belong to one continuous sound section; this judgment must be documented. RQD depends on drilling quality, core diameter, fracture orientation, recovery and the interpretation of discontinuities. Large core loss or poor sampling can make an RQD estimate unrepresentative. High RQD also does not rule out a weak clay-filled shear zone.
Other measures, such as solid core recovery, fracture frequency and strength testing, may be required by the project’s core-logging scheme. Their definitions should be stated rather than assumed to be identical across standards.
Fractures, Discontinuities and Core Box Organization
A core tray is a physical archive of the subsurface investigation. Each compartment should show the borehole ID, drilling run, top and bottom depths, correct direction of increasing depth, core loss and any deliberately inserted spacers. Photograph a clean, labeled box with a scale before material is destructively sampled.

For each relevant discontinuity, describe whether it is natural, induced or uncertain; its infill, surface condition and water features; and any reliable orientation. In unoriented vertical core, a fracture’s apparent angle to the core axis is not the same as its true strike and dip. A core-box photo is especially valuable where fault gouge, broken zones, lithological contacts and narrow weathered bands might otherwise be overlooked.
Groundwater and Drilling Observations
Groundwater information requires a timestamp and an explanation of drilling conditions. The first water strike, the water level measured during drilling, and the stabilized level in a properly installed monitoring point are not necessarily the same. Water, foam or drilling mud introduced into a hole can alter the apparent level; low-permeability layers may respond slowly. Artesian or perched conditions can also occur.
- Record depth and time for first encountered seepage or inflow, where observable.
- Record water added during drilling, fluid loss, casing intervals and any obstruction that affects the observation.
- Repeat observations after drilling when feasible, stating elapsed time and measurement reference.
- Use appropriately designed piezometers or monitoring wells where a representative equilibrium level or seasonal variation is required.
- Do not draw a continuous regional water table from a single transient drilling observation.
The worked diagram below marks groundwater at 6.3 m as an invented educational example only. In an actual investigation, the value would be accompanied by the observation date, method and relevant drilling conditions.
Linking Sampling, In-Situ Tests and Laboratory Results
Borehole logs often include sampling symbols and test results such as SPT blow counts, vane shear tests, permeability tests, pressuremeter results, laboratory water content and particle-size distribution. These values must be plotted against their actual test depths, not simply placed at a convenient layer midpoint.
SPT data should distinguish the seating interval from the two subsequent penetration increments used to derive the customary N-value. Energy corrections such as N₆₀ should not be confused with the raw field blow count. The use of refusal notation, incomplete penetration and sample recovery must be explicit. CPT/CPTu data, while commonly presented in separate continuous profiles, can be correlated with borehole strata only after considering positional and geological uncertainty.

For related methods, see In-Situ Testing and Site Investigation Techniques. A final geotechnical report should refer to the test procedures and correction schemes used.
How to Read a Borehole Log
Read the header first, then follow the depth axis downward while comparing the lithology, sampling and test columns. Check which observations were made continuously and which came from discrete samples or tests. The contact between units is exact only to the degree that drilling and sampling allow; intervals without recovery must be represented transparently.

The example illustrates a fundamental reading principle: at 8 m, the plotted N-value describes the test resistance of the sampled interval, not an exact strength value for every centimetre of the whole sand-and-gravel layer. The line at 10 m marks the change to weathered limestone in this teaching profile; it is not a universal depth at which SPT should be replaced by coring.
Worked Example: Interpreting a 15 m Investigation Hole
Imagine a proposed low-rise building site where one vertical hole reaches 15 m. Its hypothetical stratigraphy and test results are listed below. The numbers and descriptions were created solely to demonstrate logging, not to recommend a foundation.
| Depth (m) | Illustrative log description | Recorded test / observation |
|---|---|---|
| 0.0–1.0 | Topsoil with roots and organic traces | Do not treat as competent bearing stratum by default |
| 1.0–4.0 | Silty sand, brown | SPT N = 8 at 2.0 m (hypothetical) |
| 4.0–7.0 | Stiff grey clay | SPT N = 13 at 5.0 m (hypothetical); water observed at 6.3 m |
| 7.0–10.0 | Sand and gravel, dense appearance | SPT N = 35 at 8.0 m (hypothetical) |
| 10.0–15.0 | Weathered limestone with variable fractures | Rock coring; log recovery, discontinuities and material description |
The log suggests a sequence of near-surface organic material, granular and cohesive soils, then weathered rock. It does not prove layer continuity, safe bearing pressure, settlement magnitude, seasonal groundwater conditions or excavation stability. Those require an appropriate number of investigations, laboratory and field testing, design loads, a conceptual ground model and engineering assessment.
Site-wide correlations should consider geology and geomorphology, trial pits, geophysics and other holes. For the broader interpretation of lithological units, see Stratigraphy.
Borehole Geophysical Logging Is Different
Downhole geophysical instruments record physical properties around a borehole, such as natural gamma radiation, electrical resistivity, conductivity, acoustic response or borehole-wall images. They may help identify intervals between core samples, fracture zones or hydrogeological changes. These measurements do not automatically identify a unique rock type, and logging performance depends on borehole diameter, fluid, casing and tool calibration.

Core scanning is a further complementary technique: imaging, spectral sensing or elemental analyses can enrich a core record, but sample depths and geological interpretation must still be checked. Where core and geophysical logs disagree, investigate calibration, depth offsets, drilling disturbance, recovery gaps and the physical property actually measured.
Quality Control: Common Borehole Logging Errors
- Ambiguous depth reference: mixing ground-level depth with casing-top or survey elevations without recording offsets.
- Invented boundaries: showing sharp contacts across core loss or between widely spaced samples as if directly observed.
- Overinterpreted descriptions: treating visual field soil identification as a verified laboratory classification.
- Misleading rock data: equating 100% core recovery with 100% RQD, or recording drilling-induced breaks as natural joints.
- Unreliable water table: reporting a drilling-water level as a stabilized piezometer measurement.
- Incomplete test annotations: omitting SPT seating blows, termination conditions, instrument or method changes.
- Untraceable photographs: core-box images without borehole ID, depth markers, orientation or scale.
- Inconsistent terminology: mixing ISO and USCS codes without clearly identifying the classification system.
A good quality-control pass compares the field sheet, driller’s log, sample labels, core photographs and laboratory schedule. The reviewer should check that the final log reconciles observations without hiding uncertainty and that the project ground model remains consistent with independent evidence.
How Borehole Logs Support Geotechnical Design
Verified logs inform the selection and interpretation of soil and rock testing, the identification of problematic layers, ground improvement decisions, groundwater control plans, retaining structures, foundation investigations and excavation support. They are inputs to design rather than finished design recommendations.
For example, a thin soft clay seam in otherwise dense deposits may control local deformation; core loss along a weathered fault zone may deserve targeted investigation; and groundwater in a permeable stratum can change excavation risks. Different foundation options need assessment of loads, stratigraphy, groundwater, settlement and construction practicality, not merely a single SPT number or RQD percentage.
A project-focused overview appears in Engineering Geology for Construction.
Geotechnical Borehole Logging FAQ
What is the difference between a borehole log and a geological cross-section?
A borehole log records the materials and measurements at one investigation location. A geological or geotechnical cross-section correlates observations between locations and therefore adds interpretation and uncertainty.
What does a high RQD mean?
A high RQD usually indicates a comparatively large proportion of sound core pieces at least as long as the specified threshold. It does not measure intact rock strength or guarantee that the rock mass has no weak or unfavourably oriented discontinuities.
Can groundwater depth be measured immediately after drilling?
A level can be observed immediately, but it may be transient because of drilling water, fluid losses, casing and slow equilibration. Monitoring installations and repeated readings may be necessary for design.
Do borehole logs include SPT and CPT results?
SPT results are commonly displayed at their sampled borehole depths. CPT and CPTu typically produce separate continuous sounding plots that may be correlated with borehole information; whether they appear on the same sheet depends on the project format.
Which standards are relevant to borehole logging?
ISO 14688-1 and -2 address soil description and classification; ISO 14689 addresses rock identification and description; ASTM D5434-25 is a guide to field logging; and FHWA manuals offer examples of field and final boring logs. Use the editions and standards specified for the project.
References and Technical Standards
- Texas Department of Transportation – Percent recovery and rock quality designation (RQD).
- ISO 14688-1:2017 — Geotechnical investigation and testing: Identification and description of soil.
- ISO 14688-2:2017 — Principles for soil classification.
- ISO 14689:2017 — Identification, description and classification of rock.
- ASTM D5434-25 — Standard Guide for Field Logging of Subsurface Explorations of Soil and Rock.
- Federal Highway Administration, Geotechnical Site Characterization (FHWA-NHI-16-072) — field logs, borehole data, sample descriptions and groundwater records.
- FHWA guidance on subsurface exploration and boring logs — content and engineering interpretation of logs.
Image notice: field photographs show real investigations or equipment from the cited sources; none is claimed to depict the fictional example borehole. Photographs have been converted or resized for the site. The two GeologyScience graphics use synthetic educational values and are explicitly labeled accordingly.