Heavy dynamic probing and percussion core equipment at the Beethovenhalle site in Bonn Germany
Heavy dynamic probing equipment (orange probe system) beside a percussion coring setup at Beethovenhalle, Bonn. Photo: Jonas Börje Lundin; CC BY-SA 4.0. Original: https://commons.wikimedia.org/wiki/File:Ramm-%20und%20Rammkernsondierung.jpg

Dynamic penetration testing is an in-situ geotechnical investigation method that drives a standardized cone into soil or weak rock with repeated hammer impacts and records the blows required for a defined advance. EN ISO 22476-2 identifies light (DPL), medium (DPM), heavy (DPH) and super-heavy (DPSH) systems. Their different hammer, cone and drive configurations mean results cannot be interchanged without a suitable interpretation framework.

Dynamic probing helps identify ground resistance variations and investigate compactness or stratigraphic transitions where the method is appropriate. It is not a direct measurement of allowable foundation pressure, an SPT test or a substitute for geotechnical borehole sampling. This article explains its field procedure, N10/N20 blow counts, energy, charts and important limitations.

What Is Dynamic Penetration Testing?

Dynamic probing — impact and cone systemConceptual, not a dimensioned manufacturer drawingHammer of specified massAnvil / guide assemblyDrive rodsStandard cone tipRecord blows for specified advancement, including partial penetrations and refusal.
Original GeologyScience technical schematic of the test principle. This is not a particular DPL/DPH/DPSH specification.

A standardized cone is coupled to rods and driven into the ground by the repeated fall of a hammer from a specified height. Field staff record impact counts for regular advancement intervals, sometimes with rotation of the rods to limit friction. Stronger ground commonly requires more blows for the same advance, but soil fabric, rod friction, obstructions and groundwater also influence the outcome.

The result is a depth-dependent resistance profile. The test generally does not recover samples or directly identify soil composition, so nearby drilling and geological descriptions are used to determine what produces a resistance change.

DPL, DPM, DPH and DPSH: Equipment Types

Published DPL dynamic penetration blow count N10 versus depth chart in German
Published example of a DPL dynamic probing result: number of blows for 10 cm penetration (N10) plotted against depth. Credit: BauingBob. Original image, photographer and reuse terms; CC BY-SA 3.0. Converted to WebP.
ISO systemNominal hammer massNominal fall heightRecorded interval
DPL — light10 kg0.50 mN10 (10 cm)
DPM — medium30 kg0.50 mN10 (10 cm)
DPH — heavy50 kg0.50 mN10 (10 cm)
DPSH-A — super-heavy63.5 kg0.50 mN10 or N20, according to report
DPSH-B — super-heavy63.5 kg0.75 mN10 or N20, according to report

These are nominal configurations described in the cited EN ISO 22476-2:2005+A1:2011 framework. Cone area, angle, rod mass, hammer guides and machine operation also differ. A local report must state the exact edition and apparatus, especially if a system is modified or the national standard has been updated.

DPL and DPH are not simply different names for the same test. The heavier apparatus imposes a different impact energy and often uses different cone geometry, so identical blow counts need not indicate identical ground resistance.

Site Setup and Step-by-Step Field Procedure

U.S. Air Force personnel using portable dynamic cone penetrometer in Hungary
Portable dynamic cone penetrometer (DCP) used in an airfield investigation in Hungary; this is a distinct method from ISO DPL/DPH/DPSH. Credit: U.S. Air Force / Andrew Bertain. Original image, photographer and reuse terms. Converted to WebP.

1. Plan the sounding. Check buried utilities, working area, groundwater conditions and ground stability. Locate the test and establish ground elevation and intended maximum depth.

2. Assemble and check. Confirm cone dimensions, rod mass, hammer mass and nominal fall height against the governing standard. A freely falling hammer and secure connections are essential for repeatable results.

3. Start driving. Set the rig approximately vertical, position the cone and begin hammer impacts. Count the blows required for each specified 10 cm or 20 cm advance; note depth changes, rod additions and any unusual conditions.

4. Address rod friction. When appropriate under the procedure, rotate rods and observe whether side resistance compromises the sound. An increase in blows due to friction must not be misinterpreted as a stronger layer.

5. Terminate and report. Stop according to the method’s relevant refusal, equipment-safety or depth criteria. Document the actual advance if a full counting interval was not completed.

Site hazards include falling hammer parts, trapping points, handling heavy rods, hidden services and unstable working platforms. Only trained field teams should operate the apparatus.

Understanding N10, N20 and Refusal

Example dynamic probing N10 profileInvented values for explanation — NOT field dataBlows per 100 mm penetration0.5 m31.0 m51.5 m82.0 m132.5 m183.0 m223.5 m304.0 m27An increase in blows suggests increasing penetration resistance, not a unique soil type.
Original synthetic GeologyScience example of N10; a real probing log must identify apparatus type and depth intervals.

N10 denotes the number of hammer blows required for a cone advance of 0.10 m; N20 denotes the blow count for 0.20 m. The commonly used 2005+A1 standard reports DPL/DPM/DPH primarily in N10, while DPSH can be reported using N10 or N20. A header that only says ‘N = 20’ without the interval and instrument is incomplete.

Example: if an appropriate DPH instrument needs 12 impacts for an advance of 100 mm, the reported value for that interval is N10 = 12 blows. The mean advancement per blow is 100/12 = 8.33 mm/blow, averaged for that particular interval.

If 50 blows advance the tip only 60 mm before a test is terminated, the observed record is ’50 blows/60 mm’ along with the reason for termination—not an invented complete N10. A boulder, cemented pocket or mechanical problem can produce apparent refusal without true bedrock being reached.

Reading a Dynamic Penetration Test Graph

US Air Force survey team assessing soil by portable cone penetration
Military team using a portable DCP test for temporary airfield ground assessment; not a standardized ISO DPH test. Credit: U.S. Air Force. Original image, photographer and reuse terms. Converted to WebP.

A standard profile plots penetration blow count against depth. The included genuine published German DPL example above illustrates the conventional style; the original GeologyScience chart is deliberately synthetic and shows how a resistance curve can change as different layers are traversed.

Lower resistance may correspond to loose granular soil, soft ground or an affected test condition, whereas high counts could reflect denser sand, gravel, stiff clay, cementation or an obstruction. Peaks, jumps and declining resistance require interpretation alongside stratigraphy, nearby boreholes and groundwater.

Comparing two curves is most meaningful when both used the same apparatus, reporting interval and field procedure. Reporting a high DPSH resistance beside a lower DPL value is not enough to demonstrate a stiffer soil without normalization or a validated comparison.

Impact Energy and Dynamic Point Resistance qd

Nominal potential energy per blow (mgh)Reference configurations from EN ISO 22476-2:2005+A1:2011DPL49.1 JDPM147.2 JDPH245.3 JDPSH-A311.5 JDPSH-B467.2 JEnergy at the hammer, not measured delivered energy at the cone.
Original calculation for nominal configurations. Energy at the cone is affected by energy losses; the bars do not imply comparable cone resistance.

The theoretical gravitational energy of one blow is E = m × g × h, where hammer mass m is in kg, gravitational acceleration g approximately 9.81 m/s² and fall height h is in metres.

Worked DPH example: a nominal 50 kg hammer dropped 0.50 m has a theoretical potential energy of 50 × 9.81 × 0.50 = 245.25 J per blow. Not all this energy is necessarily delivered to the cone because rod joints, hammer/anvil behavior and other mechanical losses occur.

Some methods derive a dynamic point resistance qd using the hammer energy, nominal cone area, penetration per blow and an impact-efficiency or mass-transfer expression. In one commonly used formulation, qd = [m/(m + m′)] × [mgh/(A e)], where m′ represents the driven assembly mass, A the cone base area and e the average penetration per blow. The calculation is model-dependent and has to follow the version adopted for the actual equipment.

A number in MPa obtained from an energy formula is a derived dynamic point resistance, not an independently measured SPT N60, a cone penetration qc or an allowable design bearing pressure.

How Rod Friction, Gravel and Groundwater Affect Results

Engineer inspecting handheld dynamic cone penetration equipment at Lajes Air Base
Handheld DCP test equipment in its case, illustrating another impact penetration tool; not an ISO 22476-2 heavy probing rig. Credit: U.S. Air National Guard. Original image, photographer and reuse terms. Converted to WebP.

The measured resistance includes cone penetration and potential energy losses. Side friction along drive rods may become substantial as depth increases, especially in cohesive soil or collapsing or deviated holes. Operational checks for rotation and rod friction improve data quality but cannot fully eliminate these effects.

Cobbles, gravel lenses and buried construction debris may produce abrupt blow-count spikes or stop the cone. Thin strong layers and underlying softer material can be masked. A high value in fill should not automatically be called intact rock.

Water pressure, saturation, drainage rate and stress history influence soil response. Dynamic probing is therefore most useful when interpreted against a sampled geological profile, rather than used to assign a soil name solely from the number of blows.

Dynamic Probing vs Handheld DCP: An Important Distinction

Marines using portable dynamic cone penetrometer to evaluate ground
A portable DCP used for airfield soil strength investigation, distinct from European DPL and DPSH tests. Credit: U.S. Marine Corps. Original image, photographer and reuse terms. Converted to WebP.

A portable Dynamic Cone Penetrometer (DCP) is frequently used in road-base, pavement and temporary airfield assessments. It may use a small hand-held hammer, cone and a measurement of millimetres penetration per blow; it is not automatically one of the EN ISO 22476-2 DPL/DPM/DPH/DPSH configurations.

The military DCP photographs in this article illustrate that separate near-surface method and are labeled accordingly. Confusing DCP photos or results with a super-heavy ISO DPSH field sound would be scientifically incorrect. For a professional report, the exact device and method must be identified.

A real short field video of light dynamic probing (DPL) shows the appropriate European technique. It is linked rather than embedded because the website media importer does not support its original WebM format.

Dynamic Probing Compared With SPT, CPT and Pressuremeter

Portable cone penetrometer used on prepared airfield construction subgrade
Portable dynamic cone penetrometer used in military construction subgrade testing; not a European DPSH rig. Credit: U.S. Air Force. Original image, photographer and reuse terms. Converted to WebP.
TestReported responseKey difference
DPL / DPH / DPSHBlows per set cone advance and optionally qdDifferent impact energies; normally no soil sampling
SPTBlows for last 300 mm of a driven split spoonConducted inside borehole and recovers disturbed sample
CPT / CPTuContinuous measured qc, fs and possibly u2Steady static penetration using an electronic sensor cone
Ménard pressuremeterBorehole cavity expansion responseMeasures pressure–volume behavior and interpreted modulus

See the scheduled Standard Penetration Test and CPT and CPTu articles, along with In-Situ Testing for context.

Site-specific correlations may relate dynamic probing resistance to compactness or other ground parameters, but such relationships must be calibrated for apparatus, soil type, groundwater and geology. A universal conversion from N10 to SPT N-values is not technically justified.

Engineering Applications and Limitations

Dynamic probing is often useful for screening variable ground, identifying changes in density of granular soils, evaluating ground-improvement uniformity and mapping shallow weak zones. It offers a relatively rapid resistance profile without drilling an open borehole in appropriate ground.

Limitations include uncertain sample identity, rod friction, refusal on cobbles, sensitivity to equipment energy and the non-unique link between blows and geotechnical properties. In clays, soft fine soils or heterogeneous ground, borehole and laboratory data become especially important.

A complete report documents equipment type, cone area, hammer and fall height, site coordinates, ground elevation, actual blow intervals, refusal, rod rotation, encountered water and quality issues. Graphic traces should label N10 or N20 rather than an ambiguous ‘N’.

Frequently Asked Questions

What is DPL? Light dynamic probing, traditionally using a nominal 10 kg hammer in the cited ISO system.

What is the difference between DPH and DPSH? They have different prescribed hammer and cone configurations and nominal impact energy; their blow counts cannot be treated as equivalent.

What does N10 mean? The number of blows required for 10 cm of penetration for the applicable dynamic probing system.

Can dynamic probing determine soil bearing capacity? Not directly; site-specific geotechnical characterization and an accepted design procedure are needed.

Is an SPT N-value equal to dynamic probing N10? No. SPT uses a different sampling system and impact protocol.

Can dynamic probing identify bedrock? A high resistance or refusal may result from a cobble or cemented layer; other observations are required.

What does qd represent? An estimated dynamic point resistance derived from penetration and energy parameters under a specified model.

Which standard governs European dynamic probing? EN ISO 22476-2:2005 with amendment A1:2011 is the referenced procedure; check the current national adoption and project edition.

Technical References and Image Credits

DIN EN ISO 22476-2:2005+A1:2011 — Dynamic Probing.

EN ISO 22476-2 sample — Equipment specifications and record intervals.

TECSO — Dynamic Penetration Testing.

Geolog4 — Dynamic Probing Results and qd Reporting.

The photo of the actual DPL results chart and the other real photographs link to their original Wikimedia Commons sources. Other field photographs depict distinctly labeled portable DCP activity. Original GeologyScience graphics and worked figures are illustrative, not project data.